Posted by : Pratt Monday 23 December 2013


Half Wave Rectifier
 Aim: To implement a Half-Wave Rectifier circuit with and without a capacitive filter and to calculate its ripple factor
Requirement:
Function Generator                             1Digital Multimeter                              1CRO (20 MHz dual)                           1Diode 1N4007                                    1Resistor 1 K                                        1Capacitor                                             1Breadboard                                         1Circuit Diagram: Activity 1: Without Capacitive Filter
Procedure:
1. Connect the circuit as shown in circuit diagram Fig.5.1
2. Apply the input sine wave of magnitude 5V(P-P) and frequency 1kHz to the rectifier      and observe the output waveform
3. Sketch the output waveform as observed in the CRO
4. Measure the output dc voltage(Vdc) and the peak output ac voltage(Vm) using the CRO and the digital
    multimeter .
5. Calculate the ripple factor using the formula given bellowγ = Vrms / Vdc
Where Vrms is the rms value of the ac component =Vm / 2

Activity 2: With Capacitive Filter
Procedure:
Procedure:
1. Connect the capacitor across the load
2. Repeat step 2 to 5 of Activity 1.
                                3. Also calculate the ripple factor using the formula and compare the result.
                                                                          
                                                                                         γ = Vrms / Vdc
 4. Sketch the input/output waveform .Conclusion:
Precaution:

VIDEO TUTORIAL ON HALF WAVE RECTIFIER